Fiberglass Insulation Manufacturer Gets Serious About Installation

One of the major fiberglass insulation manufacturers (the color in the photo below gives away which one I’m talking about) is getting serious about the installation quality of fiberglass batt insulation. They’ve put out a video (embedded below) and a document showing how to achieve RESNET Grade 1 installation quality with fiberglass batts. Have you seen these things yet?
Owens Corning’s push for Grade 1 installation
Owens Corning, of course, is the company I’m talking about. The photo above, from their 12 page guide, Achieving Grade 1 with Fiberglass Batts (pdf), shows their trademarked pink insulation. The guide begins with some general information about what it means to get to RESNET’s Grade 1 in insulation installation quality. It also includes a nice checklist that builders and insulation installers can use to help ensure they get Grade 1 when installing fiberglass batts.
The guide closes with four pages of photos on the right and wrong ways to install insulation. They hit on some of the critical areas that cause most of the problems preventing installers from getting Grade 1 assigned to their work by the home energy raters who inspect the work. Here’s one of them.
If the style of that image looks familiar, you may recognize that it’s from the ENERGY STAR Version 3 training materials. Owens Corning has referenced the ENERGY STAR Thermal Enclosure Rater Checklist (TERC) in this document so installers know why they’re getting docked, at least for ENERGY STAR homes. (Advanced Energy, which put together the ESV3 materials, also prepared this document for Owens Corning.)
The insulation installation grading protocol is from Appendix A in RESNET’s Home Energy Rating System (HERS) Standards. I wrote about how to grade installation quality of insulation a while back, so you can check that article for more details about what’s behind the grades: 1, 2, or 3. (The short version is that Grade 1 is the best, and the parameters that govern the grade are the percentage of area with missing insulation and how much compression or incompletely filled areas there are.)
A helpful video for installers
In addition to the 12 page guide, Owens Corning also produced a really nice video. In 11 minutes, they cover pretty much everything installers need to know to get to grade 1 installation quality. It’s on YouTube, but you can watch it right here, too.
A good start, but…
I think this represents good progress for the fiberglass insulation industry. Fiberglass insulation, especially in batt form, has a pretty bad reputation among home energy pros. I’m going to say something now that I’m sure will lead to some interesting discussion below: The problem isn’t the material. The problem lies in the design and installation. Fiberglass batt insulation can work just fine in assemblies designed to make good installation possible and when installers take the time to do it right. Yes, it will cost more, but as usual, you get what you pay for.
Owens Corning has made a good start. They need to push harder, though. A lot harder. They put out these materials last summer, but if you don’t know where they are, you’ll have great difficulty finding them. I looked all over the fiberglass insulation part of their website and couldn’t find them. I had to go back to an email I received last summer to dig up the links. Come on, OC. Put these things front and center so anyone going to your site will see them.
Still, kudos to Owens Corning for this start. It’s much better than trying to pretend the problem doesn’t exist or squashing negative publicity about fiberglass batts. (Oh, come on. No manufacturer would do that. Would they?)
Fiberglass insulation isn’t going away. Let’s make sure it’s done right.
Related Articles
How to Grade the Installation Quality of Insulation
The Diminishing Returns of Adding More Insulation
Who’s on Your Insulation Crew?
A Visual Guide to Why Fiberglass Batt Insulation Underperforms
Images of fiberglass insulation from Owens Corning’s guide, Achieving Grade 1 with Fiberglass Batts (pdf).
NOTE: Comments are moderated. Your comment will not appear below until approved.
This Post Has 38 Comments
Comments are closed.
Totally agreed it’s
Totally agreed it’s installation issue, but also think this material should only be used (if at all – we don’t and won’t if I’m being fully transparent) if it’s in conjunction with some serious air-sealing work being done via a flash of foam, exterior foam, smart-materials being used as air barriers on exteriors, etc, etc.
I have been a GC for many
I have been a GC for many years and have never understood how stapling paper faced insulation to the side of the studs instead of on the face is acceptable. The insulation is being compressed along both sides by 1". I know that it is faster for the installer and sheetrockers hate face-nailing of insulation, but I usually insist on my homes.
WOW- us spray foam
WOW- us spray foam contractors (at least in part) fear this knowledge because it is installed badly in most homes, usually by sub sub contractors, and is a large part of its reputation of not being sufficient in harsh weather. Also since it is handled and crushed from the end of the assembly line(chopped) crunched into bundles and crunched into homes,its fluffy (valuable)start is diminished in the whole process. I know at one time it’s R-Value was tested in a "scientific process" including a vacuum chamber. I wonder if this is still allowed? Noone I know lives in a vacuum so it didn’t seem like a fair test that would help consumers make better choices. Yes, the install matters, air blowing past it on the paper edging negates the value . Maybe a seal of caulk all along the stapled area would accomplish this fully. Love this discussion on Fiberglass Insulation
My favorite comparison is one
My favorite comparison is one that I heard many years ago. The same material is used as insulation in one case and as a furnace filter in another. I agree that batt insulation needs to have air infiltration stopped by other means. That means sealing the wall cavities in stick framed construction. I use only monolithic precast concrete panels in my homes so this is not an issue.
Thanks to serious education
Thanks to serious education by Southface and others, we have been wholeheartedly trying to install fiberglass batts to grade 1 standards for several years. Inspections by code enforcers and others have demonstrated the success. One thing is clear, we have not yet arrived, but, then again, I don’t know of any other type of insulation installed perfectly. As to air sealing, we are regularly achieving 2.8 to 3.6 ACH50 under blower door tests…and we use only can spray foam, but we are tenacious with the process. The biggest issue (in my opinion) is and always has been trying to do as little as possible and get by.
Well, OC could be offering
Well, OC could be offering the higher density, higher R-Value batts they sell in Canada. That would show some commitment to better performance. <br /> <br />How about it OC?
All pre-formed insulation
All pre-formed insulation (batts, boards, panels, etc.) used within wall studs are predicated on having a uniform space to fill. This is error #1. There are no uniform spaces within wall studs (bows, twists, non-plumb corners, etc.) so the installation of any pre-formed insulation will never be completely Grade 1 nor will it be over time as wood moves. Hence the superiority of dense-pack and spray foam for wall cavities and board/panel exterior insulation for new construction and deep-energy retrofits. So, again, the question is "do you want a quick, cheap, or good solution (pick 1)"? Pre-formed is the cheap solution.
Something else (based on the
Something else (based on the above photos) – why would anyone use fiberglass insulation between the rough opening and frame of doors and windows when there is the much superior low-pressure foam? I guess because OC does not sell low-pressure foam insulation – which makes this whole effort that much more dubious.
Totally agreed it’s
Totally agreed it’s installation issue, but also think this material should only be used (if at all – we don’t and won’t if I’m being fully transparent) if it’s in conjunction with some serious air-sealing work being done via a flash of foam, exterior foam, smart-materials being used as air barriers on exteriors, etc, etc.
I have been a GC for many
I have been a GC for many years and have never understood how stapling paper faced insulation to the side of the studs instead of on the face is acceptable. The insulation is being compressed along both sides by 1″. I know that it is faster for the installer and sheetrockers hate face-nailing of insulation, but I usually insist on my homes.
WOW- us spray foam
WOW- us spray foam contractors (at least in part) fear this knowledge because it is installed badly in most homes, usually by sub sub contractors, and is a large part of its reputation of not being sufficient in harsh weather. Also since it is handled and crushed from the end of the assembly line(chopped) crunched into bundles and crunched into homes,its fluffy (valuable)start is diminished in the whole process. I know at one time it’s R-Value was tested in a “scientific process” including a vacuum chamber. I wonder if this is still allowed? Noone I know lives in a vacuum so it didn’t seem like a fair test that would help consumers make better choices. Yes, the install matters, air blowing past it on the paper edging negates the value . Maybe a seal of caulk all along the stapled area would accomplish this fully. Love this discussion on Fiberglass Insulation
My favorite comparison is one
My favorite comparison is one that I heard many years ago. The same material is used as insulation in one case and as a furnace filter in another. I agree that batt insulation needs to have air infiltration stopped by other means. That means sealing the wall cavities in stick framed construction. I use only monolithic precast concrete panels in my homes so this is not an issue.
Thanks to serious education
Thanks to serious education by Southface and others, we have been wholeheartedly trying to install fiberglass batts to grade 1 standards for several years. Inspections by code enforcers and others have demonstrated the success. One thing is clear, we have not yet arrived, but, then again, I don’t know of any other type of insulation installed perfectly. As to air sealing, we are regularly achieving 2.8 to 3.6 ACH50 under blower door tests…and we use only can spray foam, but we are tenacious with the process. The biggest issue (in my opinion) is and always has been trying to do as little as possible and get by.
Well, OC could be offering
Well, OC could be offering the higher density, higher R-Value batts they sell in Canada. That would show some commitment to better performance.
How about it OC?
All pre-formed insulation
All pre-formed insulation (batts, boards, panels, etc.) used within wall studs are predicated on having a uniform space to fill. This is error #1. There are no uniform spaces within wall studs (bows, twists, non-plumb corners, etc.) so the installation of any pre-formed insulation will never be completely Grade 1 nor will it be over time as wood moves. Hence the superiority of dense-pack and spray foam for wall cavities and board/panel exterior insulation for new construction and deep-energy retrofits. So, again, the question is “do you want a quick, cheap, or good solution (pick 1)”? Pre-formed is the cheap solution.
Something else (based on the
Something else (based on the above photos) – why would anyone use fiberglass insulation between the rough opening and frame of doors and windows when there is the much superior low-pressure foam? I guess because OC does not sell low-pressure foam insulation – which makes this whole effort that much more dubious.
The failure of most building
The failure of most building materials is installation which could be directed toward the lack of serious training offered by manufacturer’s. Maybe this is their way to skate around warranty claims?
The failure of most building
The failure of most building materials is installation which could be directed toward the lack of serious training offered by manufacturer’s. Maybe this is their way to skate around warranty claims?
My hat’s off to Owens Corning
My hat’s off to Owens Corning but, what took so long? <br />This article was written in 1985, I think you will like it. <br /> <br />"R" Your Getting What You "R" Paying For <br /> <br />When choosing an insulation, don’t just compare the R-values generated under laboratory conditions. "Although the fundamental heat transmission characteristics of a material or system can be determined accurately, actual performance in a structure may vary from that indicated in the laboratory (20.3)*." The R-value of fiberglass insulation can be particularly deceiving, because the published R-values are based primarily on conductive heat. "For all types of insulating materials, conduction is not the sole mode of heat transfer (20.3)*." "The total conductance is the sum of a component resulting from radiation and a component resulting from convection and conduction combined. These components can vary independently of each other (20.8)*." <br /> <br />Fiberglass insulation manufacturers don’t like to test their products for all forms of heat transfer because "The movement of air through an insulation system, either by natural or forced convection, has a deleterious effect on thermal performance (20.2)*." "Typical leakage rates in most structures are 6 to 10 air changes per hour (22.7)*". "Air movement by infiltration through a building envelope must be limited if the space is to be maintained at a condition different from outdoors (21.9)*." "Control of infiltration is an important strategy to assure thermal comfort and minimize energy use in buildings (22.7)*." Some "insulating materials can reduce air infiltration and provide additional fire resistance and noise control. Insulation also increases interior thermal comfort by controlling interior mean radiant temperatures resulting in more uniform air temperatures within the enclosure. Proper use of insulation can reduce the size of heating, cooling and ventilating equipment, reducing initial costs as well as annual operating costs (20.14)*." "It should not be assumed that leakage through the building envelope occurs primarily at doors and windows where there are visible joints. Studies have shown that leakage attributed to windows and doors constitute only about one-fifth of the total leakage. Leakage cracks and openings in walls and ceilings, especially at intersections, although not as obvious, make a far greater contribution to total leakage. Up to 70% of the total leakage openings were in walls, and up to 67% were through the ceiling, depending on the particular structure (21.9)*." "The infiltration of a building is proportional to its leakage area. Reducing the leakage area by 20% reduces the average infiltration of the building by the same percentage (22.16)*." <br /> <br />"The effectiveness of thermal insulation is seriously impaired when it is improperly installed. Where there is a 4% void area in R-11 wall insulation, the heat loss is increased by 15%. A 4% void in the insulation of an R-19 ceiling results in an increase of 50% in heat loss.* When thin wall insulation is installed vertically with air spaces on both sides, air interchange around the insulation increases the heat loss by 60% (20.8)*." "To attain published or claimed thermal resistance values, it is essential to provide convection and infiltration barriers, to seal cracks in joints and to install insulation so that gaps and voids around and within the materials do not occur. It has been established that 3% edge gaps (stapling batts on the inside of the studs) around insulation can produce 30% loss in effective R value (20.2)*." "A continuous air infiltration barrier is one of the most effective means of reducing air leakage through walls, around windows and door frames and at joints between major building elements (22.11)*." "Effectiveness can be greatly reduced if openings, even very small ones, exist in the retarder. Such openings can be caused by poor workmanship during application, poorly sealed joints and edges, insufficient coating thickness, improper caulking and flashing, uncompensated thermal expansion, mechanical forces, aging and other forms of degradation." Even an excellent vapor retarder is of little benefit if it can be bypassed by a current of air (20.10)*." "The function of insulation is clear; it reduces energy loss from a surface operating at a temperature other than ambient. Optimum use of insulation can: (1.) reduce operating expenditures for energy, (2.) improve process efficiency, (3.) increase system output capacity or reduce required equipment capacity and its capital cost and (4.) reduce overhead, maintenance, fire and personnel insurance, and other plant expenses. The most important benefit of insulation is the energy conserved and resulting savings in fuel and power costs (20.10)*." <br /> <br />In the average structures being built using fiberglass insulation, it is not uncommon to see 45% total heat loss in walls and 50% in ceilings. These figures do not take into account any loss of R-values due to compression in the cavities, which can add up to an additional 30%. <br /> <br />*Note: The above quotations are taken from the American Society of Heating, Refrigeration and Air-conditioning Engineers (ASHRAE) Fundamentals Handbook
My hat’s off to Owens Corning
My hat’s off to Owens Corning but, what took so long?
This article was written in 1985, I think you will like it.
“R” Your Getting What You “R” Paying For
When choosing an insulation, don’t just compare the R-values generated under laboratory conditions. “Although the fundamental heat transmission characteristics of a material or system can be determined accurately, actual performance in a structure may vary from that indicated in the laboratory (20.3)*.” The R-value of fiberglass insulation can be particularly deceiving, because the published R-values are based primarily on conductive heat. “For all types of insulating materials, conduction is not the sole mode of heat transfer (20.3)*.” “The total conductance is the sum of a component resulting from radiation and a component resulting from convection and conduction combined. These components can vary independently of each other (20.8)*.”
Fiberglass insulation manufacturers don’t like to test their products for all forms of heat transfer because “The movement of air through an insulation system, either by natural or forced convection, has a deleterious effect on thermal performance (20.2)*.” “Typical leakage rates in most structures are 6 to 10 air changes per hour (22.7)*”. “Air movement by infiltration through a building envelope must be limited if the space is to be maintained at a condition different from outdoors (21.9)*.” “Control of infiltration is an important strategy to assure thermal comfort and minimize energy use in buildings (22.7)*.” Some “insulating materials can reduce air infiltration and provide additional fire resistance and noise control. Insulation also increases interior thermal comfort by controlling interior mean radiant temperatures resulting in more uniform air temperatures within the enclosure. Proper use of insulation can reduce the size of heating, cooling and ventilating equipment, reducing initial costs as well as annual operating costs (20.14)*.” “It should not be assumed that leakage through the building envelope occurs primarily at doors and windows where there are visible joints. Studies have shown that leakage attributed to windows and doors constitute only about one-fifth of the total leakage. Leakage cracks and openings in walls and ceilings, especially at intersections, although not as obvious, make a far greater contribution to total leakage. Up to 70% of the total leakage openings were in walls, and up to 67% were through the ceiling, depending on the particular structure (21.9)*.” “The infiltration of a building is proportional to its leakage area. Reducing the leakage area by 20% reduces the average infiltration of the building by the same percentage (22.16)*.”
“The effectiveness of thermal insulation is seriously impaired when it is improperly installed. Where there is a 4% void area in R-11 wall insulation, the heat loss is increased by 15%. A 4% void in the insulation of an R-19 ceiling results in an increase of 50% in heat loss.* When thin wall insulation is installed vertically with air spaces on both sides, air interchange around the insulation increases the heat loss by 60% (20.8)*.” “To attain published or claimed thermal resistance values, it is essential to provide convection and infiltration barriers, to seal cracks in joints and to install insulation so that gaps and voids around and within the materials do not occur. It has been established that 3% edge gaps (stapling batts on the inside of the studs) around insulation can produce 30% loss in effective R value (20.2)*.” “A continuous air infiltration barrier is one of the most effective means of reducing air leakage through walls, around windows and door frames and at joints between major building elements (22.11)*.” “Effectiveness can be greatly reduced if openings, even very small ones, exist in the retarder. Such openings can be caused by poor workmanship during application, poorly sealed joints and edges, insufficient coating thickness, improper caulking and flashing, uncompensated thermal expansion, mechanical forces, aging and other forms of degradation.” Even an excellent vapor retarder is of little benefit if it can be bypassed by a current of air (20.10)*.” “The function of insulation is clear; it reduces energy loss from a surface operating at a temperature other than ambient. Optimum use of insulation can: (1.) reduce operating expenditures for energy, (2.) improve process efficiency, (3.) increase system output capacity or reduce required equipment capacity and its capital cost and (4.) reduce overhead, maintenance, fire and personnel insurance, and other plant expenses. The most important benefit of insulation is the energy conserved and resulting savings in fuel and power costs (20.10)*.”
In the average structures being built using fiberglass insulation, it is not uncommon to see 45% total heat loss in walls and 50% in ceilings. These figures do not take into account any loss of R-values due to compression in the cavities, which can add up to an additional 30%.
*Note: The above quotations are taken from the American Society of Heating, Refrigeration and Air-conditioning Engineers (ASHRAE) Fundamentals Handbook
In my experience, the single
In my experience, the single point of failure for sealing stick framed buildings is the wall to foundation joint. Simply putting a foam pad between the mudsill and concrete foundation does nothing more than reduce air flow into the crawl space. Air can still move upward behind the siding and housewrap, and enter the wall cavity above. No one want to own this joint. Neither framers nor siding crews seem to know what to do. I have had some success with applying a urethane caulk along the masonry top edge, but this can interfere with wall drainage. Also, caulking the inside of the wall along the base-plate helps. Even EnergyStar rules have you seal all external wall electrical boxes as they assume you will have air movement in the wall cavity. Yet another reason that I do not stick frame outside walls anymore.
On the point of that wall-to
On the point of that wall-to-foundation joint, JLC is actually on a jobsite of ours following along as we build a sort-of-hybrid house where the addition will be highly energy-efficient and can be isolated from the old cottage we are attaching it to. I’m using a rubber gasket under the sill plates now for this very reason. It’s the only material I use now. I’ll try to attach a link to that piece here. This house will be airtight with smart membranes and dense-packed throughout the walls and roof. http://www.jlconline.com/energyefficient-construction/a-net-zero-addition-on-cape-cod_o.aspx?dfpzone=coastal&utm;_source=newsletter&utm;_content=jump&utm;_medium=email&utm;_campaign=COCO_011315&day;=2015-01-13&he;=568b299884f239ae2371ccf6d35ac8aeb5db98bf
Mike, you are missing my
Mike, you are missing my point. The joint UNDER the sill (mud) plate and on the foundation is not the issue. It is from the mud-sill upward that is my concern. Now perhaps if the rubber gasket were to extend toward the outside several inches and could be folded upward and fastened onto the outside sheathing prior to attaching the housewrap, you might be onto something. Hold the housewrap short a couple of inches and then use builder’s tape to attach the housewrap to your gasket. I like that.
Gotcha Thom, same page with
Gotcha Thom, same page with you now. We’ll actually be doing something similar to that on this one. Our air barrier is going to wrap down the exterior, over that gasket, and through a series of steps with primers and tapes actually attach to the concrete foundation below the gasket. Notjing will ever be perfect, but we’re working towards it and by doing so getting better and better.
In my experience, the single
In my experience, the single point of failure for sealing stick framed buildings is the wall to foundation joint. Simply putting a foam pad between the mudsill and concrete foundation does nothing more than reduce air flow into the crawl space. Air can still move upward behind the siding and housewrap, and enter the wall cavity above. No one want to own this joint. Neither framers nor siding crews seem to know what to do. I have had some success with applying a urethane caulk along the masonry top edge, but this can interfere with wall drainage. Also, caulking the inside of the wall along the base-plate helps. Even EnergyStar rules have you seal all external wall electrical boxes as they assume you will have air movement in the wall cavity. Yet another reason that I do not stick frame outside walls anymore.
On the point of that wall-to
On the point of that wall-to-foundation joint, JLC is actually on a jobsite of ours following along as we build a sort-of-hybrid house where the addition will be highly energy-efficient and can be isolated from the old cottage we are attaching it to. I’m using a rubber gasket under the sill plates now for this very reason. It’s the only material I use now. I’ll try to attach a link to that piece here. This house will be airtight with smart membranes and dense-packed throughout the walls and roof. http://www.jlconline.com/energyefficient-construction/a-net-zero-addition-on-cape-cod_o.aspx?dfpzone=coastal&utm;_source=newsletter&utm;_content=jump&utm;_medium=email&utm;_campaign=COCO_011315&day;=2015-01-13&he;=568b299884f239ae2371ccf6d35ac8aeb5db98bf
Mike, I will have to be very
Mike, I will have to be very skeptical of bonding anything directly to concrete, especially with tapes. I really like the concept of using the gasket turned upward onto the wall face and using tape with mechanical fasteners to tie it into the house wrap. That connection would be totally protected from the weather and be part of the water shedding plain.
Mike, you are missing my
Mike, you are missing my point. The joint UNDER the sill (mud) plate and on the foundation is not the issue. It is from the mud-sill upward that is my concern. Now perhaps if the rubber gasket were to extend toward the outside several inches and could be folded upward and fastened onto the outside sheathing prior to attaching the housewrap, you might be onto something. Hold the housewrap short a couple of inches and then use builder’s tape to attach the housewrap to your gasket. I like that.
Gotcha Thom, same page with
Gotcha Thom, same page with you now. We’ll actually be doing something similar to that on this one. Our air barrier is going to wrap down the exterior, over that gasket, and through a series of steps with primers and tapes actually attach to the concrete foundation below the gasket. Notjing will ever be perfect, but we’re working towards it and by doing so getting better and better.
Mike, I will have to be very
Mike, I will have to be very skeptical of bonding anything directly to concrete, especially with tapes. I really like the concept of using the gasket turned upward onto the wall face and using tape with mechanical fasteners to tie it into the house wrap. That connection would be totally protected from the weather and be part of the water shedding plain.
Folks when it comes to air
Folks when it comes to air-sealing OC has a product called energy complete that gets the ACH50 in the 1.5 to 2.5 range consistently when installed properly. They are addressing the air-leakage issues.
This has all been very
This has all been very interesting. From my view, I deal with insulating the sill by spraying foam where possible in unfinished basements and crawls because that is what I do , a sort of retrofit fix long after construction is completed and the home has settled and the wood has contorted to allow mother nature in. Sure I can seal baseboards and receptacles and around windows,and doors from wall air entry to the living spaces, but the many homes that were built previously don’t have the technology you modern day builders are discussing here! I always tell clients that I am not a builder, just a retrofitter. I hope OC and other companies follow this airseal movement but I distrust its ability to stop conduction, convection and radiation all simultaneously. Roxul seems to be a better choice because it is more of a ductile material and really expands fully when its packaging is removed. Glas fibers do not heal themselves after being crushed into bags, bundles and trucks,then attics and walls. A drinking glass filled with steamy hot water feels like hot but in a styro foam cup feels better. Hope that made sense! I also don’t believe that subs that install fiberglass care or are trained to care about long term results- seems like a take the money and run mentality for some. I even see batts missing in walls with my thermal camera and also mis directed( paper not facing the conditioned spaces)I think the industry has a long way to go, maybe this spray foam alternative has given them reason to look again. Great discussion her guys, I love to hear modern day builders discuss these things when their motives are for their customer’s comfort in the long term.
I just checked on
I just checked on energyComplete and LOL <br />Matt Risinger4 months ago <br /> <br />Luke, I’m no longer using this system or promoting it. They have re-formulated the way it’s applied and I’m not a fan. This house blew around 2.5ACH50 but I’m not sure their reformulated system would produce those results. 
Folks when it comes to air
Folks when it comes to air-sealing OC has a product called energy complete that gets the ACH50 in the 1.5 to 2.5 range consistently when installed properly. They are addressing the air-leakage issues.
This has all been very
This has all been very interesting. From my view, I deal with insulating the sill by spraying foam where possible in unfinished basements and crawls because that is what I do , a sort of retrofit fix long after construction is completed and the home has settled and the wood has contorted to allow mother nature in. Sure I can seal baseboards and receptacles and around windows,and doors from wall air entry to the living spaces, but the many homes that were built previously don’t have the technology you modern day builders are discussing here! I always tell clients that I am not a builder, just a retrofitter. I hope OC and other companies follow this airseal movement but I distrust its ability to stop conduction, convection and radiation all simultaneously. Roxul seems to be a better choice because it is more of a ductile material and really expands fully when its packaging is removed. Glas fibers do not heal themselves after being crushed into bags, bundles and trucks,then attics and walls. A drinking glass filled with steamy hot water feels like hot but in a styro foam cup feels better. Hope that made sense! I also don’t believe that subs that install fiberglass care or are trained to care about long term results- seems like a take the money and run mentality for some. I even see batts missing in walls with my thermal camera and also mis directed( paper not facing the conditioned spaces)I think the industry has a long way to go, maybe this spray foam alternative has given them reason to look again. Great discussion her guys, I love to hear modern day builders discuss these things when their motives are for their customer’s comfort in the long term.
I just checked on
I just checked on energyComplete and LOL
Matt Risinger4 months ago
Luke, I’m no longer using this system or promoting it. They have re-formulated the way it’s applied and I’m not a fan. This house blew around 2.5ACH50 but I’m not sure their reformulated system would produce those results.
Just attending IBS I found
Just attending IBS I found this new item…problem solved. <br />http://www.foams.saint-gobain.com/Gasketing/Accuframe.aspx
Just attending IBS I found
Just attending IBS I found this new item…problem solved.
http://www.foams.saint-gobain.com/Gasketing/Accuframe.aspx